Overview
Heat pump sizing from the building heat load: required output incl. hot water and utility blocking times, bivalence point from the manufacturer capacity curve, GModG hybrid share and BEG efficiency checks, annual electricity estimate. Required heating output = (design heat load + mean hot-water load) x 24 / (24 - blocking hours). Hot water energy per day = volume x density (Kell 1975) x 4.18 kJ/(kg K) x temperature rise.
Protocol
x402 (POST)
Price
$0.0030
Payment Asset
USD Coin
Payment Network
eip155:8453
Category
uncategorized
Provider
rechen
Indexed
2026-11-21 05:10:45
Health
Status
unknown
Latency (p50)
—
Uptime (30d)
—
Reliability Score
—
Last Checked
Never
Last Healthy
Never
Consecutive Failures
0
Input Schema
{
"body": {
"blocking_hours_per_day": 2,
"capacity_curve": [
{
"capacity_kw": 5,
"outdoor_c": -15
},
{
"capacity_kw": 6,
"outdoor_c": -7
},
{
"capacity_kw": 7.5,
"outdoor_c": 2
},
{
"capacity_kw": 8.5,
"outdoor_c": 7
}
],
"design_heat_load_kw": 8,
"design_outdoor_temp_c": -12,
"hot_water": {
"litres_per_day": 200
}
},
"bodyType": "json",
"method": "POST",
"type": "http"
}
Output Schema
{
"example": {
"limitations": [
"Information computed by formula and statutory rules from the stated parameters; not legal, tax, funding or energy advice and no substitute for planning by a qualified professional.",
"The heat load, design outdoor temperature and capacity data are inputs; the linear load line ignores solar and internal gains below the heating limit.",
"Seasonal performance and coverage shares need a climate-based method (e.g. VDI 4650) that is not reproduced here."
],
"result": {
"assumptions": [],
"bivalence_point_c": -5.88,
"blocking_factor": 1.0909,
"capacity_at_design_kw": 5.375,
"checks": [],
"design_coverage_percent": 67.2,
"design_heat_load_kw": 8,
"hot_water": {
"energy_kwh_per_day": 9.286,
"mean_load_kw": 0.3869
},
"legal_basis": {
"checked": "2026-11-01",
"norms": [
"§ 43(5) GModG",
"BEG EM TMA Nr. 3.4"
],
"parameters_valid": {
"beg_from": "2026-07-21",
"beg_to": "2030-12-31"
},
"sources": [
"https://www.gesetze-im-internet.de/geg/",
"https://www.bundesanzeiger.de/pub/publication/jLXvW09kHTQoDINAdoC/content/jLXvW09kHTQoDINAdoC/BAnz%20AT%2027.08.2026%20B1.pdf?inline"
],
"version": "GModG as amended 23.07.2026; BEG EM guideline of 17.08.2026 (BAnz AT 27.08.2026 B1)"
},
"load_line": {
"design_outdoor_c": -12,
"heating_limit_c": 15,
"load_at_2_kw": 3.8519,
"load_at_7_kw": 2.3704,
"load_at_minus_7_kw": 6.5185
},
"required_output_kw": 9.149,
"steps": [
"Required output = (8 + 0.3869) x 24/(24 - 2) = 9.149 kW.",
"Load line: 8 kW at -12 °C to 0 at 15 °C; bivalence point where capacity = load: -5.88."
]
},
"service": "heat-pump-sizing",
"status": "success"
},
"type": "json"
}