Heat pump sizing from the building heat load: required output incl. hot water an...

https://rechen.halowerk.com/v1/heat-pump-sizing

Overview

Heat pump sizing from the building heat load: required output incl. hot water and utility blocking times, bivalence point from the manufacturer capacity curve, GModG hybrid share and BEG efficiency checks, annual electricity estimate. Required heating output = (design heat load + mean hot-water load) x 24 / (24 - blocking hours). Hot water energy per day = volume x density (Kell 1975) x 4.18 kJ/(kg K) x temperature rise.

Protocol x402 (POST)
Price $0.0030
Payment Asset USD Coin
Payment Network eip155:8453
Category uncategorized
Provider rechen
Source bazaar
Indexed 2026-11-21 05:10:45

Health

Status unknown
Latency (p50) —
Uptime (30d) —
Reliability Score —
Last Checked Never
Last Healthy Never
Consecutive Failures 0

x402 Payment Validation

Payment Requirements —
Asset Verified —
Facilitator —

Input Schema

{ "body": { "blocking_hours_per_day": 2, "capacity_curve": [ { "capacity_kw": 5, "outdoor_c": -15 }, { "capacity_kw": 6, "outdoor_c": -7 }, { "capacity_kw": 7.5, "outdoor_c": 2 }, { "capacity_kw": 8.5, "outdoor_c": 7 } ], "design_heat_load_kw": 8, "design_outdoor_temp_c": -12, "hot_water": { "litres_per_day": 200 } }, "bodyType": "json", "method": "POST", "type": "http" }

Output Schema

{ "example": { "limitations": [ "Information computed by formula and statutory rules from the stated parameters; not legal, tax, funding or energy advice and no substitute for planning by a qualified professional.", "The heat load, design outdoor temperature and capacity data are inputs; the linear load line ignores solar and internal gains below the heating limit.", "Seasonal performance and coverage shares need a climate-based method (e.g. VDI 4650) that is not reproduced here." ], "result": { "assumptions": [], "bivalence_point_c": -5.88, "blocking_factor": 1.0909, "capacity_at_design_kw": 5.375, "checks": [], "design_coverage_percent": 67.2, "design_heat_load_kw": 8, "hot_water": { "energy_kwh_per_day": 9.286, "mean_load_kw": 0.3869 }, "legal_basis": { "checked": "2026-11-01", "norms": [ "§ 43(5) GModG", "BEG EM TMA Nr. 3.4" ], "parameters_valid": { "beg_from": "2026-07-21", "beg_to": "2030-12-31" }, "sources": [ "https://www.gesetze-im-internet.de/geg/", "https://www.bundesanzeiger.de/pub/publication/jLXvW09kHTQoDINAdoC/content/jLXvW09kHTQoDINAdoC/BAnz%20AT%2027.08.2026%20B1.pdf?inline" ], "version": "GModG as amended 23.07.2026; BEG EM guideline of 17.08.2026 (BAnz AT 27.08.2026 B1)" }, "load_line": { "design_outdoor_c": -12, "heating_limit_c": 15, "load_at_2_kw": 3.8519, "load_at_7_kw": 2.3704, "load_at_minus_7_kw": 6.5185 }, "required_output_kw": 9.149, "steps": [ "Required output = (8 + 0.3869) x 24/(24 - 2) = 9.149 kW.", "Load line: 8 kW at -12 °C to 0 at 15 °C; bivalence point where capacity = load: -5.88." ] }, "service": "heat-pump-sizing", "status": "success" }, "type": "json" }