← Back to directory

Component compatibility for a dental implant system: its own abutment screw and ...

https://probeline.io/v1/implants/compatibility

Overview

Component compatibility for a dental implant system: its own abutment screw and multi-unit torques and driver, manufacturer-declared cross-system compatibility with sources, and similar interfaces flagged unverified.

Protocol x402 (POST)
Price $0.10
Payment Asset USD Coin
Payment Network eip155:8453
Category uncategorized
Provider ProbeLine
Source bazaar
Indexed 2026-11-17 04:03:10

Health

Status unknown
Latency (p50) —
Uptime (30d) —
Reliability Score —
Last Checked Never
Last Healthy Never
Consecutive Failures 0

x402 Payment Validation

Payment Requirements —
Asset Verified —
Facilitator —

Input Schema

{ "body": { "id": "blue-sky-bio-internal-hex" }, "bodyType": "json", "method": "POST", "type": "http" }

Output Schema

{ "example": { "implant": { "id": "blue-sky-bio-internal-hex", "line": "BIO | Internal Hex", "manufacturer": "Blue Sky Bio" }, "manufacturer_declared_compatibility": [ { "claim": "Manufacturer states implants, prosthetics and instrumentation are fully compatible with Implant Direct Legacy.", "declared_by": "Blue Sky Bio", "direction": "this system claims compatibility with", "exceptions": [], "platform": null, "scope": [ "surgical", "prosthetic", "instruments" ], "source": "https://blueskybio.com/store/internal-hex-implant-packs", "system": { "id": "implant-direct-legacy", "line": "Legacy (Legacy1/2/3/4, simplyLegacy)", "manufacturer": "Implant Direct (Envista)" } }, { "claim": "Manufacturer states implants, prosthetics and instrumentation are fully compatible with Zimmer Tapered Screw-Vent.", "declared_by": "Blue Sky Bio", "direction": "this system claims compatibility with", "exceptions": [ "5.7 mm implants are not compatible with Zimmer drills." ], "platform": null, "scope": [ "surgical", "prosthetic", "instruments" ], "source": "https://blueskybio.com/store/internal-hex-implant-packs", "system": { "id": "zimvie-tsv", "line": "Tapered Screw-Vent (TSV)", "manufacturer": "ZimVie" } } ], "native_components": { "connection": "internal hex", "driver": null, "mua_prosthetic_screw_torque_ncm": null, "mua_torque_ncm": null, "platforms": [ { "abutment_screw_torque_ncm": 30, "diameter_mm": 3.5, "implant_diameters_mm": [ 3.7, 4.1, 4.7, 5.7 ], "name": "3.5", "torque_confidence": "verified", "torque_source": "https://www.BlueSkyBio.com/caffeine/uploads/files/documents/BS-LS-0001%20BSB%20Dental%20Implant%20IFU%20Specification%20-%20Rev%205%20Attachment.pdf" } ], "sources": [ "https://blueskybio.com/store/internal-hex-implant-packs", "https://blueskybio.com/store/implants_1", "https://www.BlueSkyBio.com/caffeine/uploads/files/documents/BS-LS-0001%20BSB%20Dental%20Implant%20IFU%20Specification%20-%20Rev%205%20Attachment.pdf" ] }, "notes": [ "Manufacturer-declared cross-system compatibility only. Absence of a claim means none was found, not that parts are incompatible. Every claim cites the declaring manufacturer's document.", "similar_interface_unverified lists systems with the same connection family and a platform diameter within 0.1 mm. This is NOT a compatibility claim: index geometry, cone angle and screw thread differ between manufacturers.", "Use the restoring system's own abutment screw and torque value. Verify against the current IFU before ordering or torquing." ], "ok": true, "similar_interface_unverified": [ { "connection": "internal hex", "diameter_mm": 3.5, "id": "biohorizons-tapered-pro", "line": "Tapered Pro", "manufacturer": "BioHorizons", "platform": "3.5" } ] }, "type": "json" }