Overview
Conductor mass is calculated from nominal cross-section, core count and length against the material density; for a nominal cross-section this is exact and independent of stranding. Total cable mass and the copper share are returned as a range derived from published manufacturer weight tables per cross-section band, not as a type-test value. Insulation, filler and armour are not modelled individually.
Protocol
x402 (POST)
Price
$0.0020
Payment Asset
USD Coin
Payment Network
eip155:8453
Category
uncategorized
Provider
cable_conductor_mass
Indexed
2026-08-14 07:12:21
Health
Status
healthy
Latency (p50)
374ms
Uptime (30d)
100.0%
Reliability Score
95/100
Last Checked
2026-10-31 07:10:58
Last Healthy
2026-10-31 07:10:58
Consecutive Failures
0
Input Schema
{
"body": {
"cable_type": "NYM-J",
"cores": 3,
"cross_section_mm2": 1.5,
"length_m": 100
},
"bodyType": "json",
"method": "POST",
"type": "http"
}
Output Schema
{
"example": {
"assumptions": [
"Conductor mass uses the nominal cross-section; stranded and solid conductors of the same nominal size are treated alike.",
"Total cable mass is a range from published weight tables per cross-section band, not a type-test value.",
"Filler, armour and screens other than a stated concentric conductor are not modelled."
],
"band_used": "klein",
"cable_mass_kg_estimate": {
"high": 12.096,
"low": 8.87
},
"cable_type": "NYM-J",
"concentric_conductor_mass_kg": null,
"conductor_mass_kg": 4.032,
"conductor_mass_kg_per_m": 0.0403,
"conductor_material": "copper",
"conductor_share_percent": {
"high": 45.5,
"low": 33.3
},
"cores": 3,
"cross_section_mm2": 1.5,
"density_g_per_cm3": 8.96,
"length_m": 100,
"mass_ratio_used": {
"high": 3,
"low": 2.2
},
"method": "geometry x density, sheath factor by cross-section band",
"sheath": "PVC",
"standard": "VDE 0250-204",
"unavailable_fields": []
},
"type": "json"
}