Combine individual loss percentages into a total system loss using PVWatts multi...
https://www.brainiac.software/api/v1/solar-design/system-loss-stackOverview
Combine individual loss percentages into a total system loss using PVWatts multiplicative derating, with optional defaults for missing categories. Docs: https://www.brainiac.software/api/solar-design/system-loss-stack
Protocol
x402 (POST)
Price
$0.01
Payment Asset
USD Coin
Payment Network
eip155:8453
Category
uncategorized
Provider
PVWatts System Loss Percentages
Source
bazaar
Indexed
2026-11-24 19:01:16
Health
Status
unknown
Latency (p50)
—
Uptime (30d)
—
Reliability Score
—
Last Checked
Never
Last Healthy
Never
Consecutive Failures
0
x402 Payment Validation
Payment Requirements
—
Asset Verified
—
Facilitator
—
Input Schema
{
"body": {
"losses": {
"age": 0,
"availability": 3,
"connections": 0.5,
"lid": 1.5,
"mismatch": 2,
"nameplate": 1,
"shading": 3,
"snow": 0,
"soiling": 2,
"wiring": 2
},
"useDefaultsForMissing": true
},
"bodyType": "json",
"method": "POST",
"type": "http"
}
Output Schema
{
"example": {
"derate": 0.8592433931173553,
"items": [
{
"name": "soiling",
"percent": 2,
"source": "caller"
},
{
"name": "shading",
"percent": 3,
"source": "caller"
}
],
"limitations": [
"Outputs are design-stage calculations on caller-supplied inputs for human review. They are not engineering stamps, code compliance determinations, or utility",
"Losses combine multiplicatively per PVWatts v5: total = 100·[1 − Π(1 − l_i/100)]."
],
"sources": [
{
"retrievedAt": "2026-11-14",
"source": "Caller-supplied module, inverter, irradiance and site inputs processed locally",
"status": "ok",
"url": "https://www.brainiac.software/api/v1/solar-design"
},
{
"retrievedAt": "2026-11-14",
"source": "PVWatts Version 5 Manual (Dobos 2014, NREL/TP-6A20-62641)",
"status": "ok",
"url": "https://www.nrel.gov/docs/fy14osti/62641.pdf"
}
],
"totalPercent": 14.075660688264469
},
"type": "json"
}