Reconstruct Polychromatic dual-energy CT nonlinear spectral material-path invers...
https://detect.halowerk.com/v1/F-TD2000-GEO-INDUSTRY-B026/polychromatic-dual-energy-alvarez-macovski-material-path-reconstructionOverview
Reconstruct Polychromatic dual-energy CT nonlinear spectral material-path inversion from an anonymous supplied artifact and compare an explicit claim.
Protocol
x402 (POST)
Price
$0.0030
Payment Asset
USD Coin
Payment Network
eip155:8453
Category
uncategorized
Provider
detect
Source
bazaar
Indexed
2026-11-02 17:25:42
Health
Status
unknown
Latency (p50)
—
Uptime (30d)
—
Reliability Score
—
Last Checked
Never
Last Healthy
Never
Consecutive Failures
0
x402 Payment Validation
Payment Requirements
—
Asset Verified
—
Facilitator
—
Input Schema
{
"body": {
"artifact": {
"alvarezCT": {
"claim": null,
"data": {
"high_energy_spectral_bins": [
[
70,
0.5,
0.8,
1
],
[
90,
0.3,
0.7,
1
]
],
"low_energy_spectral_bins": [
[
30,
2,
1,
1
],
[
40,
1.5,
0.9,
1
]
],
"measured_log_attenuations": [
1.355915045438,
0.68219013277
],
"unattenuated_photon_counts": [
100000,
200000
]
}
}
}
},
"bodyType": "json",
"method": "POST",
"type": "http"
}
Output Schema
{
"example": {
"billable": true,
"findings": [
{
"confidence": 1,
"evidence": [
{
"page_indices": [],
"page_url": null,
"pattern": "polychromatic-dual-energy-alvarez-macovski-material-path-reconstruction_scoped_evidence",
"type": "artifact"
}
],
"limits": [
"Caller-supplied bounded technical model only; every numeric result rounded to six decimal places before exact claim comparison. No external fetch, safety, legal, or medical decision."
],
"module": "polychromatic-dual-energy-alvarez-macovski-material-path-reconstruction",
"state": "observed",
"value": {
"alvarezCT": {
"Jacobian_determinant": 0.910661,
"Poisson_coefficient_Fisher_information": [
[
91503.7198,
71340.775721
],
[
71340.775721,
79234.595656
]
],
"coefficient_Cramer_Rao_covariance": [
[
0.000037,
-0.000033
],
[
-0.000033,
0.000042
]
],
"expected_photon_counts": [
25771.136891,
101101.729608
],
"inverse_material_Jacobian": [
[
0.819468,
-1.035831
],
[
-0.431021,
1.884844
]
],
"log_attenuation_Hessians": [
[
[
-0.061375,
-0.012275
],
[
-0.012275,
-0.002455
]
],
[
[
-0.009944,
-0.004972
],
[
-0.004972,
-0.002486
]
]
],
"log_attenuation_Jacobian": [
[
1.716454,
0.943291
],
[
0.392514,
0.746257
]
],
"log_attenuation_residual": [
0,
0
],
"material_path_coefficients": [
0.4,
0.7
],
"reconstructed_log_attenuations": [
1.355915,
0.68219
],
"relative_transmissions": [
0.257711,
0.505509
],
"spectral_convention": "Two disjoint incident x-ray spectra represented by finite energy bins. Each row=[energy_keV,positive_basis1,positive_basis2,incident_weight]. Basis attenuation values are caller supplied dimensionless data, not inferred tissue/material properties. I_j(A)/I_j(0)=sum w exp(-A1*b1-A2*b2)/sumw, L_j=-log(I_j/I_j0). Reconstruct the unique nonnegative two-component path from paired L; strict low/high b1/b2 separation ensures monotonic distinct level curves. Poisson counts independent, Fisher is mathematical expected count information. No scatter, pileup, medical image or actual composition claim.",
"transmitted_spectral_probabilities": [
[
0.432907,
0.567093
],
[
0.46257,
0.53743
]
]
},
"claim_matches": false
},
"warnings": []
}
],
"known_count": 1,
"scope": {
"contact_values_returned": false,
"network": false,
"supplied_artifact_only": true
},
"warnings": []
},
"type": "json"
}