← Back to directory

Radiator flow rates for hydraulic balancing: from room heat loads and radiator r...

https://rechen.halowerk.com/v1/hydraulic-balance

Overview

Radiator flow rates for hydraulic balancing: from room heat loads and radiator ratings (EN 442 characteristic with exponent) the lowest system flow temperature, required flow per radiator (kg/h, l/h), return temperatures and the critical room. Each radiator output follows Q = Q_N x (dT_ln / dT_ln,N)^n with the logarithmic mean temperature difference dT_ln = (t_v - t_r) / ln((t_v - t_i) / (t_r - t_i)) and the caller’s rating point (default 75/65/20 °C) and exponent.

Protocol x402 (POST)
Price $0.0030
Payment Asset USD Coin
Payment Network eip155:8453
Category uncategorized
Provider rechen
Source bazaar
Indexed 2026-11-21 05:10:45

Health

Status unknown
Latency (p50) —
Uptime (30d) —
Reliability Score —
Last Checked Never
Last Healthy Never
Consecutive Failures 0

x402 Payment Validation

Payment Requirements —
Asset Verified —
Facilitator —

Input Schema

{ "body": { "radiators": [ { "id": "living", "rated_output_w": 1000, "room_heat_load_w": 600 }, { "id": "bedroom", "rated_output_w": 1500, "room_heat_load_w": 600 } ] }, "bodyType": "json", "method": "POST", "type": "http" }

Output Schema

{ "example": { "limitations": [ "Information computed by formula and statutory rules from the stated parameters; not legal, tax, funding or energy advice and no substitute for planning by a qualified professional.", "Pipe pressure losses, valve presettings (kv values) and pump selection need manufacturer data and are not computed.", "The EN 442 characteristic with a constant exponent is an approximation, best near the rating point." ], "result": { "assumptions": [], "constants": { "cp_kj_kgk": 4.18, "density": "Kell (1975) at mean water temperature" }, "critical_radiator": "living", "legal_basis": { "checked": "2026-11-01", "norms": [ "§ 60c GModG (hydraulic balancing duty from six units)", "BEG EM TMA (hydraulic balancing as funding condition)" ], "parameters_valid": { "valid": "physical method, no time-dependent parameters" }, "sources": [ "https://www.gesetze-im-internet.de/geg/" ], "version": "GModG as amended by the Act of 23.07.2026; physics per EN 442 characteristic (caller data)" }, "mixed_return_c": 48.17, "mode": "lowest_supply", "radiators": [ { "covered": true, "flow_kg_h": 103.35, "flow_l_h": 104.78, "id": "living", "output_at_rating_ratio": 0.6, "return_c": 51.2, "room_heat_load_w": 600, "spread_k": 5 }, { "covered": true, "flow_kg_h": 25.36, "flow_l_h": 25.63, "id": "bedroom", "output_at_rating_ratio": 0.4, "return_c": 35.83, "room_heat_load_w": 600, "spread_k": 20.37 } ], "steps": [ "Lowest flow temperature so that every radiator covers its load with at least 5 K spread: 56.2 °C (critical: living).", "Each radiator: return temperature from Q_load = Q_N (dT_ln/dT_ln,N)^n; mass flow = Q / (c_p (t_v - t_r))." ], "supply_temperature_c": 56.2, "total_flow_kg_h": 128.71, "undersized": [] }, "service": "hydraulic-balance", "status": "success" }, "type": "json" }